How do I read Trane furnace error codes?
Trane furnaces show a fault as either a counted red-LED flash pattern on the furnace control board (older, non-communicating models) or as a 'CL2.xxx' alert code on the communicating thermostat (XV/XC/XL/S systems).
How to read Trane furnace codes
Trane furnaces show a fault as either a counted red-LED flash pattern on the furnace control board (older, non-communicating models) or as a 'CL2.xxx' alert code on the communicating thermostat (XV/XC/XL/S systems). On LED boards a slow green flash means normal/no call for heat and a fast green flash a normal call for heat; the red LED counts out the fault number. The flash-code chart is printed inside the furnace's lower access panel — your model's chart is the authoritative reference.
Trane furnace code list
| Code | What it means (tap for fixes) |
|---|---|
| 3 Flashes | Retries or recycles exceeded — the control reached the maximum number of ignition retries or flame recycles and stopped trying to light. |
| 4 Flashes | Inducer or pressure switch error — the draft inducer/pressure switch did not prove proper venting (e.g. the pressure switch failed to close). |
| 5 Flashes | Open limit or rollout switch — a high-temperature limit or flame-rollout safety switch has opened, indicating overheating or flame rollout. |
| 6 Flashes | Flame sensed when no flame should be present — the control detects a flame signal when none should exist. |
| 7 Flashes | Line reverse polarity — the incoming 115V line voltage polarity is reversed (line and neutral swapped) or there is a grounding problem. |
| 8 Flashes | Gas valve circuit error — the control detected a fault in the gas-valve circuit (e.g. open or shorted wiring, or an unexpected valve voltage state). |
| 9 Flashes | Weak flame — the flame-current sense signal is low, indicating a weak or poorly sensed flame. |
| Both LEDs solid on | Fuse open or internal control failure — the board's fuse is open (often from a low-voltage wiring short) or the integrated furnace control has an internal failure. A technician should locate the short before replacing the fuse. |
| CL2.020 / CL2.022 (Recycle / Retry) | Communicating-system alert: burners light and flame is proven, then flame drops out and the control recycles; CL2.022 is the lockout after the maximum recycles/retries. Usually a dirty flame sensor, disturbed flame, or restricted secondary heat exchanger. |
| CL2.026.01 (High Limit) | Communicating-system alert: open high-limit switch — the furnace overheated, typically from low airflow (dirty filter, dirty blower, blocked coil) or a restricted flue. Never bypass the limit switch. |
| CL2.087.00 (Rollout Open) | Communicating-system alert: open flame rollout — flames rolled out of the burner area, a serious combustion/venting problem. Stop using the furnace and call a licensed technician; never reset a rollout switch yourself. |
| CL2.092.00 (Check Fuse) | Communicating-system alert: the 24V control-board fuse is open, usually from a short in the low-voltage field wiring. A technician must find the short before replacing the fuse. |
Printable Trane code card
The whole code list on one page, with each blink pattern drawn out. Print it and tape it inside the furnace door, so the next time the light blinks you can match it on the spot.